IGNITER REPLACEMENT
1. For a front burner, remove the ring grate and top grate from the burner that needs the replacement igniter. For a rear
burner, remove the ring grates and top grates from both the front and rear burners.
2. Within the burner cavity, locate and disconnect the orange lead wire by pulling on the plastic connector.
3. Remove the burner assembly and attached venturi tube from the burner cavity by pulling it up and towards the back of
the range until it is free.
4. Turn over the burner assembly and use a Phillips screwdriver to remove the screw that attaches the igniter to the
burner head. Remove the igniter.
5. Insert the new igniter into the burner assembly, making sure it is aligned properly with the burner ports.
6. Secure the igniter to the burner assembly with the same screw.
7. Reinstall the burner assembly:
a. Lean over and look inside the burner cavity to see the round brass orifice which supplies the gas to the
burner.
b. Slide the burner head assembly into the burner cavity, making sure the open end of the metal venturi tube
(attached to the burner head) fits over the brass orifice.
c. The burner head should be level, with the two prongs on the bottom of the burner head seated through the
holes on the burner support.
8. Reconnect the two orange lead wires with the plastic connector.
The wires should be located under the burner supports, and not pinched between the burner head
and support.
Make sure the wires are not resting on the drip pan.
9. Test the unit for proper operation.